Brasil

Authors

DOI:

https://doi.org/10.29384/rbfm.2025.v19.19849001856

Keywords:

Brasil

Abstract

Computed Tomography is a widely used diagnostic tool, performed on various types of patients. However, when it comes to the pediatric population, conducting the exam can present specific challenges, especially regarding the child’s cooperation during the procedure. Due to the need for high-quality images and the equipment’s sensitivity to movement, sedation often becomes indispensable to ensure a successful exam. Nonetheless, this approach involves several risks and limitations, such as image degradation caused by sedation devices, the clinical risks associated with sedation itself, reliance on the availability of a specialized anesthesiologist, and the need for post-exam care. Because of these factors, many institutions choose, whenever possible, to avoid sedation and allow the presence of a caregiver in the exam room as an alternative to promote containment and comfort for the child. This caregiver assumes the role of reassuring and containing the child; however, this practice introduces a new concern regarding radiation protection, since the individual present in the room is potentially exposed to scattered radiation emitted by the child. Therefore, this study aimed to evaluate, based on the annual dose limits for members of the public established by the Brazilian National Nuclear Energy Commission (CNEN), the levels of scattered radiation to which caregivers are exposed during pediatric computed tomography procedures. The results showed that without the use of personal protective equipment (PPE), the effective dose to caregivers for pediatric head, mastoid, and abdomen (without contrast) protocols was approximately 38, 19, and 12 µSv, respectively. Additionally, a 94% reduction in scattered radiation dose was observed for the same protocols with the use of PPE.

Downloads

Download data is not yet available.

References

1. WESOLOWSKI JR, Lev MH. CT: History, Technology, and Clinical Aspects. Semin. Ultrasound CT MRI. 2005;26:376-379.

2. Berland LL, Smith JK. Multidetector-Array CT: Once Again,Techology Creates New Opportunities. Radiol. 1998; 209:327-329.

3. LUÍS, Gaspar Domingos; POZZO, Lorena. ID075 Panorama quantitativo do uso de Tomógrafo Computadorizado no Sistema Único de Saúde do Brasil de 2019 a 2022: EIXO 3: EQUIDADE E ACESSO. JORNAL DE ASSISTÊNCIA FARMACÊUTICA E FARMACOECONOMIA, v. 9, n. s. 1, 2024.

4. ICRP. International Commission On Radiological Protection. The 2007 recommendations of the International Commission on Radiological Protection. Exeter: Elsevier, 2007. (ICRP Publication 103).

5. THUKRAL, Brij Bhushan. Problems and preferences in pediatric imaging. Indian Journal of Radiology and Imaging, v. 25, n. 04, p. 359-364, 2015.

6. NOONAN, Sarah; SPUUR, K.; NIELSEN, S. Immobilisation in Australian paediatric medical imaging: a pilot study. Radiography, v. 23, n. 2, p. e34-e40, 2017.

7. BELLOLIO, M. Fernanda et al. Incidence of adverse events in paediatric procedural sedation in the emergency department: a systematic review and meta-analysis. BMJ open, v. 6, n. 6, p. e011384, 2016.

8. ARTUNDUAGA, Maddy et al. Safety challenges related to the use of sedation and general anesthesia in pediatric patients undergoing magnetic resonance imaging examinations. Pediatric radiology, v. 51, p. 724-735, 2021.

9. MAHMOUD, Mohamed; TOWE, Christopher; FLECK, Robert J. CT chest under general anesthesia: pulmonary, anesthetic and radiologic dilemmas. Pediatric Radiology, v. 45, n. 7, p. 977- 981, 2015.

10. OVERHOFF, Daniel et al. Radiation dose of chaperones during common pediatric computed tomography examinations. Pediatric Radiology, v. 50, p. 1078-1082, 2020.

11. OKUNO, Emico; YOSHIMURA, Elisabeth Mateus. Física das radiações. Oficina de textos, 2016.

12. ICRP. International Commission on Radiological Protection. The 1990 recommendations of the International Commission on Radiological Protection. Oxford: Pergamon Press, 1991. (ICRP Publication 60).

13. ICRP. International Commission on Radiological Protection. Conversion coefficients for use in radiological protection against external radiation. Exeter: Elsevier, 1996. (ICRP Publication 74).

14. COMISSÃO NACIONAL DE ENERGIA NUCLEAR (CNEN). CNEN NN 3.01: requisitos básicos de radioproteção e segurança radiológica de fontes de radiação. Diário Oficial da União: seção 1, Brasília, DF, 18 abr. 2024.

15. BIEGAŁA, Michał et al. Analysis of dose distribution around a computed tomography scanner in terms of exposure to scattered ionizing radiation of caregivers of pediatric patients. International Journal of Occupational Medicine and Environmental Health, v. 37, n. 3, p. 326, 2024.

Published

2025-12-02

How to Cite

José Ravel Campos Lima, Brasil, B., Brasil, B., & Brasil, B. (2025). Brasil. Brazilian Journal of Medical Physics, 19, 856. https://doi.org/10.29384/rbfm.2025.v19.19849001856

Issue

Section

Artigo Original

Similar Articles

<< < 10 11 12 13 14 15 16 17 > >> 

You may also start an advanced similarity search for this article.