Script development for analysis of lung SBRT treatment plans and its impact on the radiotherapy workflow
DOI:
https://doi.org/10.29384/rbfm.2026.v20.19849001895Palavras-chave:
Radiotherapy, Eclipse, ESAPI, Risk Management, Optimization, Lung SBRTResumo
The automation of processes in radiotherapy is an increasingly discussed topic regarding optimization and safety in this field. This study describes the development of a script for the evaluation of lung SBRT radiotherapy treatment plans in Eclipse TPS v13.6 and analyzes its impact on the workflow of a large radiotherapy institution. The software was developed in a network station external from the hospital’s database, with Eclipse v15.1 and Visual Studio Community, in C# via ESAPI. For the system`s validation, 10 recent lung SBRT cases from the institution were evaluated and the parameters obtained manually were directly compared with those obtained with the script. The evaluation of the tool’s impact on the workflow was conducted by measuring the time it took for 8 medical physicists of the institution to evaluate the plan, with and without the script and the data was statistically analyzed by the paired t-test and Shapiro-Wilk. There was a statistically significant change observed in the plans’ evaluation time, with an average reduction of 63±28%. With that, it was possible to conclude that the use of an automated tool for the treatment plans’ evaluation acts as a safety barrier by both the standardization of processes and use of protocols in the institution and also contributes to the optimization of the process.
Downloads
Referências
1. Abdel-Wahab M, Gondhowiardjo SS, Rosa AA, Lievens Y, El-Haj N, Polo Rubio JA, et al. Global radiotherapy: current status and future directions - white paper. JCO Global Oncology. 2021 Jun;7(7):827–42.
2. Marks LB, Ten Haken RK, Martel MK. Guest editor’s introduction to QUANTEC: a users guide. International Journal of Radiation Oncology Biology Physics. 2010 Mar;76(3):S1–2.
3. Timmerman R. A Story of Hypofractionation and the Table on the Wall. International Journal of Radiation Oncology Biology Physics. 2022 Jan;112(1):4–21.
4. International Commission on Radiation Units and Measurements (ICRU). Prescribing, Recording and Reporting Photon Beam Therapy. ICRU Report 50. Bethesda, MD: ICRU; 1993.
5. Bezjak A, Papiez L, Bradley J, Gore E, Gaspar L, Spring FM. Radiation Therapy Oncology Group RTOG 0813 seamless phase I/II study of stereotactic lung radiotherapy (SBRT) for early stage, centrally located, non-small cell lung cancer (NSCLC) in medically inoperable patients. 2012.
6. Videtic GMM, Hu C, Singh AK, Chang JY, Parker W, Olivier KR, et al. NRG Oncology RTOG 0915 (NCCTG N0927): A Randomized Phase II Study Comparing 2 Stereotactic Body Radiation Therapy (SBRT) Schedules for Medically Inoperable Patients with Stage I Peripheral Non-Small Cell Lung Cancer. International journal of radiation oncology, biology, physics [Internet]. 2015 Nov 15 [cited 2022 Feb 22];93(4):757–64. Available from: https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4744654/
7. Pyyry J, Keranen WW. A handbook for programming in the Varian oncology software ecosystem. In: The Legrand Orange Book: Varian APIs. 2018.
8. Varian Medical Systems. Eclipse Scripting API Reference Guide. Palo Alto, CA: Varian Medical Systems. 2015.
9. Kimsey F, McKay J, Gefter J, Milano MT, Moiseenko V, Grimm J, et al. Dose-Response Model for Chest Wall Tolerance of Stereotactic Body Radiation Therapy. Seminars in Radiation Oncology. 2016 Apr;26(2):129–34.
10. Agostinelli S, Zefiro D, Garelli S, Cavagnetto F, Gusinu M, Bevegni M, et al. BreastWatch: A Varian Eclipse script tool for Community‐Based automatic evaluation of breast treatment plans. Journal of Applied Clinical Medical Physics. 2025 Apr 1;26(6):e70080–0.
11. Liu H, Praveen Nuksani, Rajagopalan M, Patil M, Komanduri K, Murphy B, et al. Improvement in plan quality after Implementation of clinical goals in a large network of cancer centers. Medical dosimetry. 2023 Jan 1;48(1):51–4.
Downloads
Publicado
Como Citar
Edição
Seção
Licença
Copyright (c) 2026 Victor Gurgel da Fonseca, Maíra Ribeiro dos Santos, Lucas de Brito Cavalcanti, Marina de Arruda Botelho

Este trabalho está licenciado sob uma licença Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
A submissão de artigos originais para a Revista Brasileira de Física Médica implica na transferência, pelos autores, dos direitos de publicação impressa e digital. Os direitos autorais para os artigos publicados são do autor, com direitos do periódico sobre a primeira publicação. Os autores somente poderão utilizar os mesmos resultados em outras publicações indicando claramente este periódico como o meio da publicação original. Em virtude de sermos um periódico de acesso aberto, permite-se o uso gratuito dos artigos em aplicações educacionais, científicas, não comerciais, desde que citada a fonte.
A Revista Brasileira de Física Médica está sob a Licença Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0).