Proposal for Area Monitoring as an Alternative to Radiometric Surveying in Mobile Radiological Equipment
DOI:
https://doi.org/10.29384/rbfm.2025.v19.19849001847Keywords:
area monitoring, radiation protection survey, mobile x-ray equipment, radiation protection, dose limitsAbstract
This study aimed to evaluate area monitoring as an alternative to conventional radiation protection survey in the context of using mobile radiological equipment in hospitals. Air kerma and air kerma rate measurements were conducted in four radiology departments, involving nine C-arms and eight mobile X-ray units. In the bedside radiography scenario, the maximum number of weekly exposures that a patient—considered a member of the public in this context—could receive in an adjacent bed was estimated. In the context of procedures using surgical C-arms, the maximum daily exposure time for occupationally exposed individuals (OEIs) near the scattered radiation field was calculated. The calculations were based on the dose limits established by national regulatory requirements ANVISA RDC 611 and CNEN NN 3.01. The study confirms that the requirement for radiometric surveys of mobile radiological equipment can be addressed through the area monitoring methodology proposed in this study.
Downloads
References
1. Comissão Nacional de Energia Nuclear (CNEN). Norma NN 3.01: Diretrizes Básicas de Proteção Radiológica. Rio de Janeiro: 2014.
2. International Atomic Energy Agency (IAEA). Radiation protection and safety in medical uses of ionizing radiation. IAEA Safety Standards Series No. SSG-46. Vienna: 2018.
3. Agência Nacional de Vigilância Sanitária (ANVISA). Resolução RDC nº 611, de 9 de março de 2022, Brasília: 2022.
4. International Commission on Radiological Protection. Conversion Coefficients for use in Radiological Protection against External Radiation. ICRP Publication 74. Ann. ICRP 26 (3-4). 1996.
5. International Commission on Radiological Protection. Radiological Protection in Fluoroscopically Guided Procedures Performed Outside the Imaging Department. ICRP Publication 117. Ann. ICRP 40 (6). 2010.
6. Christodoulou EG, Goodsitt MM, Larson SC, Darner KL, Satti J, Chan HP. Evaluation of the transmitted exposure through lead equivalent aprons used in a radiology department, including the contribution from backscatter. Med Phys. 2003;30(6):1033-38.
7. Agência Nacional de Vigilância Sanitária (ANVISA). Instrução Normativa nº 90, de 27 de maio de 2021. Brasília: 2022.
8. Agência Nacional de Vigilância Sanitária (ANVISA). Instrução Normativa nº 91, de 27 de maio de 2021. Brasília: 2022.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2025 Antônio Portilho Daud, Rennan , Alessandro Ramos Junior, Lorena Daudt Fontoura, Regina Bitelli Medeiros, Marcelo Mariano da Silva, Marcelo Baptista de Freitas

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
The submission of original articles to the Brazilian Journal of Medical Physics implies the transfer, by the authors, of the rights of print and digital publication. Copyright for published articles remains with the author, with journal rights on first publication. Authors may only use the same results in other publications by clearly indicating this journal as the original publisher. As we are an open access journal, free use of articles in educational, scientific, non-commercial applications is allowed, as long as the source is cited.
The Brazilian Journal of Medical Physics is under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License (CC BY-NC-ND 4.0).