Evaluation of the optimization process of the CT protocol for chest and brain examinations in a university hospital
DOI:
https://doi.org/10.29384/rbfm.2026.v20.19849001873Keywords:
Computed tomography, Quality Control, optimization, protocolsAbstract
Computed tomography (CT) is an imaging diagnostic method that uses ionizing radiation, being one of the main sources of radiation exposure to which one can be subjected today. Despite its benefits, such as high-quality images and more accurate diagnoses, CT involves considerable doses of radiation. This work addresses the optimization of computed tomography (CT) protocols for chest and brain examinations in adult patients, focusing on reducing the radiation dose without compromising the image quality. The study was conducted at the Hospital das Clínicas of the Federal University of Pernambuco (HC-UFPE), using a Philips Incisive CT scanner. Protocol optimization was carried out through modifications in technical parameters such as current-time product (mAs) and pitch. These changes were tested using a phantom to evaluate variations in CTDIvol, noise, and contrast-to-noise ratio (CNR). For the CT protocol for chest examinations, five suggestions were made. Among them, suggestion number five stood out as the most efficient, presenting the lowest dose per volume (CTDIvol) and the best image quality in terms of CNR and noise. However, compared to the original protocol, suggestion five is not the best option for clinical use. In the case of the CT protocol for brain examinations, five protocol suggestions were also made, and the most prominent one was the protocol number 1, considered the best option for the clinical setting. One of the challenges faced was the need to balance radiation dose reduction with maintaining image quality, which is essential for the clinical effectiveness of CT exams. The study followed ANVISA regulations and international recommendations for quality control in computed tomography.
Downloads
References
1. Mourão AP. Tomografia computadorizada: tecnologias e aplicações. Difusão Editora, 2018.
2. United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR). Sources and effects of ionizing radiation. Scientific Annex A. Report to the General Assembly. Vol. I. United Nations; 2022.
3. Freitas GR. Metodologia de baixo custo para avaliação da dose de radiação ionizante em exames de tomografia computadorizada [dissertação de mestrado]. São Paulo (SP): Instituto de Pesquisas Energéticas e Nucleares; 2022.
4. Silva PP; Marcones AL. Otimização da dose de radiação ionizante em tomografia computadorizada. Tekhne e Logos, v. 9, n. 1, p. 88-98, 2018
5. Agência Nacional de Vigilância Sanitária (ANVISA). Instrução Normativa IN nº 93, de 27 de maio de 2021. Brasília: Diário Oficial da União; 2021 [citado 2024 jul. 02]. Disponível em: https://www.in.gov.br/en/web/dou/-/instrucao-normativa-in-n-93-de-27-de-maio-de-2021-323016253.
6. Seeram E. Computed tomography: physical principles, clinical applications and quality control. 4th ed. Missouri: Elsevier; 2015.
7. International Atomic Energy Agency (IAEA). Protocolos de control de calidad para radiodiagnóstico en América Latina y el Caribe. Vienna: IAEA; 2021.
8. American Association of Physicists in Medicine (AAPM). Performance evaluation of computed tomography systems: report of AAPM Task Group 233. AAPM; 2019.
9. International Commission on Radiological Protection (ICRP). Diagnostic reference levels in medical imaging: ICRP Publication 135. London: Sage Publications; 2017.
10. International Commission on Radiation Units and Measurements (ICRU). Radiation dose and image-quality assessment in computed tomography: Report 87. Oxford: Oxford University Press; 2012.
11. American association of physicists in medicine. Use of Water Equivalent Diameter for Calculating Patient Size and Size-Specific Dose Estimates (SSDE) in CT. The Report of AAPM Task Group 220. AAPM 2014.
12. International commission on radiological protection. Managing Patient Dose in Computed Tomography: ICRP Publication 87. Oxford: Pergamon, 2000..
13. Camargo GE. Desenvolvimento de fantoma para teste de controle de qualidade da modulação de corrente em tomografia computadorizada [dissertação de mestrado]. Curitiba (PR): Universidade Tecnológica Federal do Paraná; 2023.
14. MicroDicom Ltd. MicroDicom DICOM Viewer. Sofia, Bulgária. Disponível em: https://www.microdicom.com/. Acesso em: 03 jun. 2026.
15. Sociedad Valenciana de Protección Radiológica y Radiofísica. Manual de procedimientos de control de calidad en radiodiagnóstico. Valencia: Generalitat Valenciana, Conselleria de Sanitat; 2002.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2026 Priscila S Amorim, Tiago da Silva Jornada, Brunno Florencia de Oliveira, Divanizia do Nascimento Souza, Linda Viola Ehlin Caldas

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
The submission of original articles to the Brazilian Journal of Medical Physics implies the transfer, by the authors, of the rights of print and digital publication. Copyright for published articles remains with the author, with journal rights on first publication. Authors may only use the same results in other publications by clearly indicating this journal as the original publisher. As we are an open access journal, free use of articles in educational, scientific, non-commercial applications is allowed, as long as the source is cited.
The Brazilian Journal of Medical Physics is under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License (CC BY-NC-ND 4.0).